Thermally Conductive Insulator Selection Guide

Do not select a thermally conductive insulator solely by whether it insulates. Also compare the installation structure, thickness, thermal resistance, withstand voltage, puncture resistance, handling and operating environment. Caps and sleeves cover specific components, while polyimide and fiberglass materials suit thin, flat or custom-cut interfaces.

先確認安裝形態

Confirm the Installation Form

Thermally conductive insulators are available as three-dimensional covers or flat insulation sheets. Select the form according to the component shape, heat sink structure and assembly method.

KEY POINT
  • Transistor or power-component shape
  • Flat contact or three-dimensional coverage
  • Need for component positioning
  • Heat sink-to-component contact method
  • Installation space and working direction
TIPS

Do not select a cap or sleeve by component name alone. Confirm the package dimensions, thickness and heat sink structure. For flat materials, check the cut profile and hole-position tolerances.

確認電氣與結構功能

Check Operating Voltage and Insulation

Confirm sufficient electrical isolation based on the equipment operating voltage, safety clearances and regulatory requirements.

KEY POINT
  • Dielectric breakdown voltage
  • Dielectric breakdown
  • Volume resistivity
  • Actual material thickness
  • Creepage and clearance distances
TIPS

Dielectric strength is generally expressed per unit thickness and is not the finished part’s withstand voltage. Evaluate the actual thickness, processed condition and safety factor.

選擇適當厚度

Compare Thickness and Thermal Resistance

A thinner material generally shortens the heat-transfer path, but thickness also affects insulation, puncture resistance and the ability to accommodate surface tolerances.

KEY POINT
  • Original material thickness
  • Actual contact thermal resistance
  • Surface flatness
  • Insulation safety margin
  • Contact condition after assembly
TIPS

Thinner is not always better. With an excessively thin material, burrs, metal protrusions and uneven fastening pressure may increase the risk of puncture and insulation failure.

確認機構空間與貼附結構

Select the Material Structure

Polyimide and fiberglass composites have different selection priorities. Evaluate thinness, temperature resistance, mechanical strength and processing requirements.

KEY POINT
  • Polyimide film structure
  • Fiberglass-reinforced structure
  • Silicone or non-silicone formulation
  • Thermally conductive surface coating
  • Single-layer or composite structure
TIPS

Polyimide emphasizes thinness, temperature resistance and electrical insulation. Fiberglass emphasizes reinforcement and puncture resistance. Materials with the same name may have very different thermal resistance because of different coatings and composite structures.

評估導熱係數與壓合後熱阻

Assess Mechanical Strength and Contact Surfaces

Metal burrs, screw holes, rough surfaces and concentrated pressure may damage the material or puncture the insulation layer.

KEY POINT
  • Tensile and tear strength
  • Puncture resistance
  • Metal-surface roughness
  • Fastening pressure and uniformity
  • Edge and hole strength
TIPS

Datasheet insulation values are generally obtained from intact specimens. Die-cut burrs, creases, misaligned holes and metal protrusions may reduce actual insulation performance.

評估材料形態與操作性

Assess Application and Handling

Caps and sleeves can be fitted directly for positioning. Flat sheets are available with different tack, release liners and custom die-cut options.

KEY POINT
  • Fitting or adhesive application
  • Single-sided, double-sided, or non-adhesive
  • Release liner and pull-tab design
  • Manual or automated assembly
  • Disassembly and rework requirements
TIPS

Tack mainly supports positioning during assembly and does not necessarily improve heat transfer. Excessive tack may complicate rework and damage the insulation layer during removal.

評估使用環境與特殊需求

Check Temperature and Operating Environment

The material must maintain stable heat transfer and insulation under prolonged high temperatures, thermal cycling, humidity, vibration and contamination-sensitive conditions.

KEY POINT
  • Long-term operating temperature
  • Thermal cycling
  • High temperature and humidity
  • Vibration and mechanical shock
  • Vacuum, sealed or clean environments
  • Contact with chemicals and coolants
TIPS

Maximum temperature resistance is only an initial screening value. Confirm dielectric strength, dimensions, embrittlement, delamination and thermal-resistance changes after aging.

確認阻燃與認證需求

Check Flame-Retardant and Certification Requirements

For power, automotive and industrial equipment or other safety-regulated applications, confirm the test and certification data for the specified thickness and material model.

KEY POINT
  • UL flammability rating
  • Certified thickness range
  • RoHS/REACH
  • Halogen-free requirements
  • Automotive or industrial reliability requirements
TIPS

UL certification generally applies to a specific material, thickness and operating condition. Certification of one product does not mean the entire series has the same certification.

Quick Selection Guide

Application Recommended Category / Material
Three-dimensional coverage for transistors and power components Caps / sleeves
Fast fitting with less manual alignment Caps / sleeves
Very small gaps and thin cooling structures Polyimide
High-temperature environments and thin insulation Polyimide
Metal burrs or concentrated pressure Fiberglass reinforcement
Large areas, holes or custom die-cut shapes Fiberglass reinforcement
Contamination-sensitive or optical equipment Non-silicone, low-outgassing grade
Power and safety-compliance applications Flame-retardant / UL-certified grade
導熱絕緣材料選型指南:帽套、聚醯亞胺與玻璃纖維補強材料
導熱絕緣材料選型指南:帽套、聚醯亞胺與玻璃纖維補強材料

Choose the Right Thermally Conductive Insulator

Polyimide film and fiberglass-reinforced structures combine heat transfer, electrical insulation and mechanical strength. Select according to thinness, low thermal resistance, high-temperature resistance, puncture resistance and die-cutting requirements. Suitable for flat interfaces and complex profiles.

聚醯亞胺/玻璃纖維
以聚醯亞胺薄膜或玻璃纖維補強結構兼顧導熱、絕緣與機械強度,可依薄型低熱阻、耐高溫、抗穿刺及模切操作需求選擇,適合平面介面與複雜輪廓。
FEATURE
vertical_align_center

Thin and Low Resistance

reduces the distance from component to heat sink.

flash_off

Electrical Isolation

Isolates live components from metal cooling structures.

device_thermostat

Thermal Stability

Suits prolonged high temperatures and thermal cycling.

surgical

Reinforced Structure

Fiberglass improves tensile and puncture resistance.

tile_medium

Custom Die Cutting

Supports holes, custom shapes and large-area processing.

STEPS
導熱絕緣材料選型指南:帽套、聚醯亞胺與玻璃纖維補強材料
1

Confirm the Material

確認材質

Select by thickness, temperature resistance, insulation and puncture resistance.

導熱絕緣材料選型指南:帽套、聚醯亞胺與玻璃纖維補強材料
2

Clean the Surfaces

清潔表面

Remove metal debris, dust, oil and sharp protrusions.

導熱絕緣材料選型指南:帽套、聚醯亞胺與玻璃纖維補強材料
3

Remove the bottom liner

撕除底膜

Remove the first release liner according to the product structure.

導熱絕緣材料選型指南:帽套、聚醯亞胺與玻璃纖維補強材料
4

Align and place

對位貼附

Align with the component, holes and heat sink, then apply flat.

5

Assemble and Inspect

組裝檢查

Fasten evenly and check for wrinkles, damage or displacement.

APPLICATION
電源供應器

Power modules

MOSFET/IGBT

MOSFET/IGBT

電池模組

battery management systems

馬達控制器

motor and inverter controls

車用電子

automotive electronics

工業電腦

industrial computers

A preformed three-dimensional structure covers transistors and power components, forming a stable thermally conductive insulation layer between the component and metal heat sink. It reduces sheet alignment, washer handling and installation displacement, making it suitable for repetitive assembly.

帽套/套管
採預成型立體結構包覆電晶體及功率元件,在元件與金屬散熱板間形成穩定的導熱絕緣層,可減少片材對位、墊圈搭配與安裝偏移,適合重複性組裝。
FEATURE
capture

Three-Dimensional Coverage

Fully isolates the component from the metal cooling structure.

delivery_truck_speed

Fast Fitting

Reduces sheet, washer and hole-alignment steps.

location_searching

Stable Positioning

Resists slipping during fastening and assembly.

vertical_align_center

Flexible Conformity

Conforms to the component and accommodates local tolerances.

tile_medium

Custom Forming

Designed to match package dimensions and structural requirements.

STEPS
導熱絕緣材料選型指南:帽套、聚醯亞胺與玻璃纖維補強材料
1

Confirm Specifications

確認規格

Check the component package, cap dimensions and thickness.

導熱絕緣材料選型指南:帽套、聚醯亞胺與玻璃纖維補強材料
2

Clean the Surfaces

清潔表面

Remove oil and foreign matter from the component and heat sink.

導熱絕緣材料選型指南:帽套、聚醯亞胺與玻璃纖維補強材料
3

Fit the Cap

套入元件

Fully cover the component in the correct direction.

導熱絕緣材料選型指南:帽套、聚醯亞胺與玻璃纖維補強材料
4

Position Against the Heat Sink

貼靠散熱板

Confirm that the cap is flat, untwisted and unfolded.

5

Fasten and Inspect

固定檢查

Apply even fastening pressure and check for extrusion or puncture.

APPLICATION
功率電晶體

power transistors

MOSFET/IGBT

MOSFET/IGBT

電源供應器

Power modules

馬達控制器

motor and inverter controls

變頻器

inverters

工業控制設備

industrial control equipment

導熱絕緣材料選型指南:帽套、聚醯亞胺與玻璃纖維補強材料
導熱絕緣材料選型指南:帽套、聚醯亞胺與玻璃纖維補強材料

Feature Overview

Thermally Conductive Insulator FAQs

How Do Caps and Sleeves Differ from Flat Insulation Sheets?

A

Caps and sleeves are preformed three-dimensional structures that directly cover specific components for fast, stable positioning. Flat materials are thinner and offer greater cutting flexibility for flat interfaces, large areas and custom shapes.

A

Consider polyimide when thinness, high-temperature resistance and lower thermal resistance are priorities. Consider fiberglass reinforcement for surfaces with burrs, higher fastening pressure, large areas or complex die-cut shapes.

A

Not necessarily. Actual cooling also depends on thickness, contact thermal resistance, surface flatness and fastening pressure. A thin, well-conformed material may outperform a thicker material with higher conductivity.

A

No. A thinner material may reduce thermal resistance but can also reduce puncture resistance and the insulation safety margin. Burrs, protrusions or uneven pressure may make an excessively thin material more likely to fail.

A

No. Dielectric strength is measured per unit thickness. Actual withstand voltage also depends on thickness, processed edges, humidity, aging and the safety factor.